Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
J Cardiothorac Surg ; 18(1): 134, 2023 Apr 11.
Article in English | MEDLINE | ID: covidwho-2305068

ABSTRACT

COVID-19 infection can lead to severe acute respiratory distress syndrome (ARDS), right ventricular (RV) failure and pulmonary hypertension. Venovenous extracorporeal membrane oxygenation (V-V ECMO) has been used for patients with refractory hypoxemia. More recently dual-lumen right atrium to pulmonary artery oxygenated right ventricular assist devices (Oxy-RVAD) have been utilized in the severe medical refractory COVID ARDS setting. Historically, animal data has demonstrated that high continuous non-pulsatile RVAD flows, leading to unregulated and unprotected circulation through the pulmonary vessels is associated with an increased risk of pulmonary hemorrhage and increased amount of extravascular lung water. These risks are heightened in the setting of ARDS with fragile capillaries, left ventricular (LV) diastolic failure, COVID cardiomyopathy, and anticoagulation. Concurrently, due to infection, tachycardia, and refractory hypoxemia, high V-V ECMO flows to match high cardiac output are often necessary to maintain systemic oxygenation. Increase in cardiac output without a concurrent increase in VV ECMO flow will result in a higher fraction of deoxygenated blood returning to the right heart and therefore resulting in hypoxemia. Several groups have suggested using a RVAD only strategy in COVID ARDS; however, this exposes the patients to the risk of pulmonary hemorrhage. We present one of the first known cases using an RV mechanical support, partial flow pulmonary circulation, oxygenated Veno-venopulmonary (V-VP) strategy resulting in RV recovery, total renal recovery, awake rehabilitation, and recovery.


Subject(s)
COVID-19 , Extracorporeal Membrane Oxygenation , Heart Failure , Heart-Assist Devices , Respiratory Distress Syndrome , Animals , Extracorporeal Membrane Oxygenation/methods , Treatment Outcome , Heart Ventricles , Heart Failure/etiology , Respiratory Distress Syndrome/etiology , Hypoxia/etiology
2.
ASAIO J ; 2023 Mar 06.
Article in English | MEDLINE | ID: covidwho-2282272

ABSTRACT

Extracorporeal membrane oxygenation (ECMO) is used in cases of severe respiratory failure refractory to medical management. Use of ECMO is increasing, along with new cannulation strategies including oxygenated right ventricular assist devices (oxy-RVADs). Multiple dual lumen cannulas are now available, which increase the potential for patient mobility and decrease the number of vascular access sites. However, dual lumen, single cannula flow can be limited by adequate inflow, requiring the need for an additional inflow cannula to meet patient demands. This cannula configuration may result in differential flows in the inflow and outflow limbs and altered flow dynamics, increasing the risk of intracannula thrombus. We describe a series of four patients treated with oxy-RVAD for COVID-19-associated respiratory failure complicated by dual lumen ProtekDuo intracannula thrombus.

3.
J Card Surg ; 37(10): 3403-3407, 2022 Oct.
Article in English | MEDLINE | ID: covidwho-1961650

ABSTRACT

BACKGROUND: Over the past decade, several minimally invasive mechanical support devices have been introduced into clinical practice to support the right ventricle (RV). Percutaneous cannulas are easy to insert, minimally invasive, and treat acute RV failure rapidly. In December 2021, the Food and Drug Administration approved a new 31 French dual lumen single cannula for use as a right ventricular assist device. AIMS: Descirbe the use of the new dual lumen percutaneous right ventricular assist device (RVAD) cannula. MATERIAL AND METHODS: Deployment of the RVAD can be done surgically or percutaneously. This cannula, manufactured by Spectrum, is dual staged. It has inflow ports positioned both in the right atrium (RA) as well as the RV for maximal drainage of the right heart. The distal end of the cannula which includes the outflow port is positioned in the pulmonary artery (PA). RESULTS: Deployment of the Spectrum RVAD can be done percutaneously with transesophageal and flouroscopy guidence. Cannulation requires requisite wire skills in order to navigate into the main pulmonary artery. Utilization of this cannula can be done in acute RV failure secondary to ischemia, post cardiotomy shock, acute respiratory failure or other causes of isolated RV failure. DISCUSSION: The dual stage drainage design optimizes venous drainage as well as limits suck-down events. Theoretically, direct RV decompression also decreases RV dilation and wall tension, and facilitates improved transmural pressure gradient to reduce RV strain. CONCLUSION: Here we describe the first-in-man successful use of the dual-stage RA and RV to PA Spectrum cannula in a patient with severe COVID acute respiratory distress syndrome and acute right ventricular failure, bridged to recovery.


Subject(s)
COVID-19 , Heart Failure , Heart-Assist Devices , Ventricular Dysfunction, Right , Heart Atria/surgery , Heart Failure/surgery , Heart Ventricles/surgery , Heart-Assist Devices/adverse effects , Humans , Prosthesis Implantation/adverse effects , Pulmonary Artery/surgery , Treatment Outcome , Ventricular Dysfunction, Right/etiology
SELECTION OF CITATIONS
SEARCH DETAIL